Enphase IQ8AC Microinverter 366W Three-Phase – 54 to 72 Cell, 366 VA Peak Power, MC4 Integrated
HomeStore

Enphase IQ8AC Microinverter 366W Three-Phase – 54 to 72 Cell, 366 VA Peak Power, MC4 Integrated

Enphase IQ8AC Microinverter 366W Three-Phase – 54 to 72 Cell, 366 VA Peak Power, MC4 Integrated

$74.50

Original: $212.85

-65%
Enphase IQ8AC Microinverter 366W Three-Phase – 54 to 72 Cell, 366 VA Peak Power, MC4 Integrated

$212.85

$74.50

The Story

The Enphase IQ8AC Microinverter (Three-Phase Installation) (model IQ8AC-72-M-INT) is the IQ8AC fitted in a three-phase IQ Cable system for balanced distribution across 230/400 V three-phase supplies. Each microinverter outputs a single phase at 230 V L-N — but by connecting units in groups of three using the three-phase IQ Cable, the installed array is automatically balanced across L1, L2, and L3. This makes the IQ8AC an effective and DNO-compliant solution for commercial rooftops, larger residential properties, and any G99-notified installation requiring a balanced three-phase connection. The microinverter itself is rated at 366 W maximum AC output, 97.3% peak efficiency, operates at -40°C to +65°C with an IP67 enclosure, and is certified to G98, G99, and G100. Source: UK datasheet DSH-00198-5.0, March 2026.

366 W
Max AC Per Unit
30 Units
Per 3-Phase 20A Circuit
18 Units
Per 3-Phase IQ Cable Section
IP67
Enclosure Rating
25 Years
Limited Warranty
⚠ Installer Requirement: Three-phase IQ Cable installations require the three-phase IQ Cable (Q-25-xx-3P variants) and three-phase field wireable connectors where applicable. G99 notification is required for installations above the G98 threshold. Each microinverter must be connected to the correct phase assignment on the three-phase cable to ensure phase balance. Installation by a qualified electrician is required.
⚠ Phase Balance: Each IQ8AC unit outputs single-phase 230 V L-N. The phase balance in a three-phase system is achieved by distributing units evenly across the three-phase IQ Cable — not by the microinverter itself outputting three-phase power. Total number of units across the three phases must be managed to maintain balance within DNO limits.
ℹ Three-Phase Circuit Limits: A maximum of 30 IQ8AC units can be connected per three-phase 20A circuit (10 per phase), and a maximum of 18 units per three-phase IQ Cable section (6 per phase). Centre-feeding the IQ Cable sections is recommended best practice to manage voltage rise.
Automatic Phase Balancing via 3P IQ Cable

The three-phase IQ Cable incorporates four conductors (L1, L2, L3, Neutral) in a single cable run. When microinverters plug into the three-phase cable drops, their output is automatically assigned to alternating phases in sequence — eliminating the need to manually track and assign phase connections during installation. This significantly reduces commissioning time on larger commercial arrays.

Up to 30 Units Per Three-Phase Circuit

On a standard three-phase 20A circuit with 2.5 mm² IQ Cable, up to 30 IQ8AC microinverters can be connected — giving up to 10.98 kW AC per circuit. For large commercial rooftops, multiple circuits can be combined through the IQ Gateway to build arrays far beyond the single-phase limitations.

G99 Commercial Compliance

The IQ8AC supports Power Export Limiting (G100), phase imbalance management, and loss of phase detection — features that are specifically relevant to three-phase commercial G99 applications where DNOs impose generation or export conditions. These functions are configured through the IQ Gateway Metered once CTs are installed.

Shade Tolerance on Mixed Rooftops

On commercial rooftops with equipment, skylights, or plant rooms causing partial shading, microinverter systems outperform string inverters because shading one panel does not reduce output from neighbouring panels. Each IQ8AC operates at its own MPPT, so complex shade patterns on commercial roofs are handled without optimisers or string re-designs.

Rapid Shutdown for Commercial Safety

Module-level rapid shutdown is inherent to all IQ8 microinverters — required under fire safety standards for commercial rooftop PV. When the IQ Gateway de-energises the AC bus (via the IQ Relay or IQ System Controller), each IQ8AC immediately reduces its DC operating voltage. No separate per-module rapid shutdown devices are required.

Simple Expansion of Existing Arrays

The IQ8AC uses the same IQ8 Series form factor (212 × 175 × 30.2 mm) as all other IQ8 72-cell models. This allows a three-phase system to be expanded by adding further IQ Cable branches and microinverters as available roof area or budget allows — without replacing existing units or the IQ Gateway.

Technical Specifications — IQ8AC-72-M-INT (Three-Phase Application, UK Datasheet DSH-00198-5.0)
DC Input
Typical module compatibility 54-cell/108 HC, 60-cell/120 HC, 66-cell/132 HC, 72-cell/144 HC
Min/Max input voltage 18 V / 60 V
Rated input voltage 36.5 V
Min/Max MPP voltage 28 V / 45 V
Max input current (Idcmax) 14 A
Max short-circuit input current 25 A (max module Isc: 20 A, per IEC 62548 ×1.25)
Max input power (Pdcmax) 530 W
AC Output — Three-Phase Application
Max AC output power (per unit) 366 W at 230 V L-N
Three-phase supply voltage 230/400 V (each unit outputs 230 V L-N, one phase)
Max output current (per unit) 1.59 A
Max units per three-phase 20A circuit 30 (3L+N) = 10 per phase
Max units per three-phase IQ Cable section 18 (3L+N) = 6 per phase
Nominal frequency 50 Hz (range: 45–55 Hz)
Peak efficiency 97.3%
EU weighted efficiency 96.6%
Total harmonic distortion <5%
Topology Isolated HF transformer
Mechanical & Environmental
Dimensions (H × W × D) 212 mm × 175 mm × 30.2 mm (excl. mounting brackets)
Weight (with mounting plate) 1.1 kg
Ambient temperature range -40°C to +65°C
IP rating Outdoor — IP67
Cooling Natural convection — no fans
DC connector Stäubli MC4 (integrated)
AC connector Enphase three-phase IQ Cable (Q-25-xx-3P variants)
Standards & Compliance
Grid compliance G98, G99, G100
Safety EN IEC 62109-1, EN IEC 62109-2
Product labelling CE
Limited warranty Up to 25 years (requires connected IQ Gateway)
Do IQ8AC microinverters themselves output three-phase power?
No. Each IQ8AC unit outputs single-phase 230 V L-N. The three-phase system is achieved by distributing units evenly across L1, L2, and L3 using the three-phase IQ Cable, which connects in sequence to each phase. The IQ Gateway monitors phase balance and can apply phase imbalance management (PIM) if required.
What IQ Cable do I need for a three-phase installation?
You need the three-phase IQ Cable variants — for example Q-25-17-3P-160 (for 72-cell landscape modules) or Q-25-10-3P-200 (for portrait orientation). These are four-conductor cables (L1, L2, L3, N) and include three-phase connector drops that the microinverters plug into. Three-phase field wireable connectors (Q-CONN-3P-10M / Q-CONN-3P-10F) are available for custom cable lengths.
How many IQ8AC units can I fit on one three-phase circuit?
A maximum of 30 IQ8AC units per three-phase 20A circuit (10 per phase), and a maximum of 18 units per three-phase IQ Cable section (6 per phase). Multiple circuits can be run from the same IQ Gateway.
Is G99 notification required for three-phase IQ8AC systems?
G99 applies to generation installations above 16 A per phase on a single-phase basis, or above 16 A per phase on three-phase. Given that 10 IQ8AC units per phase at 1.59 A = 15.9 A — close to the G98 threshold — most full three-phase circuit installations will require G99 notification. Always confirm with the DNO.
Does the IQ Gateway Metered support three-phase monitoring?
Yes. The IQ Gateway Metered (ENV-S-EM-230) supports three-phase consumption monitoring when paired with three CT clamps (one per phase). This enables generation, consumption, and export data to be tracked per phase and in total via the Enphase App and Installer Platform.
Enphase IQ8AC Microinverter 366W Three-Phase – 54 to 72 Cell, 366 VA Peak Power, MC4 Integrated - Image 2

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

Enphase IQ8AC Microinverter 366W Three-Phase – 54 to 72 Cell, 366 VA Peak Power, MC4 Integrated - Image 3

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

Enphase IQ8AC Microinverter 366W Three-Phase – 54 to 72 Cell, 366 VA Peak Power, MC4 Integrated - Image 4

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

Description

The Enphase IQ8AC Microinverter (Three-Phase Installation) (model IQ8AC-72-M-INT) is the IQ8AC fitted in a three-phase IQ Cable system for balanced distribution across 230/400 V three-phase supplies. Each microinverter outputs a single phase at 230 V L-N — but by connecting units in groups of three using the three-phase IQ Cable, the installed array is automatically balanced across L1, L2, and L3. This makes the IQ8AC an effective and DNO-compliant solution for commercial rooftops, larger residential properties, and any G99-notified installation requiring a balanced three-phase connection. The microinverter itself is rated at 366 W maximum AC output, 97.3% peak efficiency, operates at -40°C to +65°C with an IP67 enclosure, and is certified to G98, G99, and G100. Source: UK datasheet DSH-00198-5.0, March 2026.

366 W
Max AC Per Unit
30 Units
Per 3-Phase 20A Circuit
18 Units
Per 3-Phase IQ Cable Section
IP67
Enclosure Rating
25 Years
Limited Warranty
⚠ Installer Requirement: Three-phase IQ Cable installations require the three-phase IQ Cable (Q-25-xx-3P variants) and three-phase field wireable connectors where applicable. G99 notification is required for installations above the G98 threshold. Each microinverter must be connected to the correct phase assignment on the three-phase cable to ensure phase balance. Installation by a qualified electrician is required.
⚠ Phase Balance: Each IQ8AC unit outputs single-phase 230 V L-N. The phase balance in a three-phase system is achieved by distributing units evenly across the three-phase IQ Cable — not by the microinverter itself outputting three-phase power. Total number of units across the three phases must be managed to maintain balance within DNO limits.
ℹ Three-Phase Circuit Limits: A maximum of 30 IQ8AC units can be connected per three-phase 20A circuit (10 per phase), and a maximum of 18 units per three-phase IQ Cable section (6 per phase). Centre-feeding the IQ Cable sections is recommended best practice to manage voltage rise.
Automatic Phase Balancing via 3P IQ Cable

The three-phase IQ Cable incorporates four conductors (L1, L2, L3, Neutral) in a single cable run. When microinverters plug into the three-phase cable drops, their output is automatically assigned to alternating phases in sequence — eliminating the need to manually track and assign phase connections during installation. This significantly reduces commissioning time on larger commercial arrays.

Up to 30 Units Per Three-Phase Circuit

On a standard three-phase 20A circuit with 2.5 mm² IQ Cable, up to 30 IQ8AC microinverters can be connected — giving up to 10.98 kW AC per circuit. For large commercial rooftops, multiple circuits can be combined through the IQ Gateway to build arrays far beyond the single-phase limitations.

G99 Commercial Compliance

The IQ8AC supports Power Export Limiting (G100), phase imbalance management, and loss of phase detection — features that are specifically relevant to three-phase commercial G99 applications where DNOs impose generation or export conditions. These functions are configured through the IQ Gateway Metered once CTs are installed.

Shade Tolerance on Mixed Rooftops

On commercial rooftops with equipment, skylights, or plant rooms causing partial shading, microinverter systems outperform string inverters because shading one panel does not reduce output from neighbouring panels. Each IQ8AC operates at its own MPPT, so complex shade patterns on commercial roofs are handled without optimisers or string re-designs.

Rapid Shutdown for Commercial Safety

Module-level rapid shutdown is inherent to all IQ8 microinverters — required under fire safety standards for commercial rooftop PV. When the IQ Gateway de-energises the AC bus (via the IQ Relay or IQ System Controller), each IQ8AC immediately reduces its DC operating voltage. No separate per-module rapid shutdown devices are required.

Simple Expansion of Existing Arrays

The IQ8AC uses the same IQ8 Series form factor (212 × 175 × 30.2 mm) as all other IQ8 72-cell models. This allows a three-phase system to be expanded by adding further IQ Cable branches and microinverters as available roof area or budget allows — without replacing existing units or the IQ Gateway.

Technical Specifications — IQ8AC-72-M-INT (Three-Phase Application, UK Datasheet DSH-00198-5.0)
DC Input
Typical module compatibility 54-cell/108 HC, 60-cell/120 HC, 66-cell/132 HC, 72-cell/144 HC
Min/Max input voltage 18 V / 60 V
Rated input voltage 36.5 V
Min/Max MPP voltage 28 V / 45 V
Max input current (Idcmax) 14 A
Max short-circuit input current 25 A (max module Isc: 20 A, per IEC 62548 ×1.25)
Max input power (Pdcmax) 530 W
AC Output — Three-Phase Application
Max AC output power (per unit) 366 W at 230 V L-N
Three-phase supply voltage 230/400 V (each unit outputs 230 V L-N, one phase)
Max output current (per unit) 1.59 A
Max units per three-phase 20A circuit 30 (3L+N) = 10 per phase
Max units per three-phase IQ Cable section 18 (3L+N) = 6 per phase
Nominal frequency 50 Hz (range: 45–55 Hz)
Peak efficiency 97.3%
EU weighted efficiency 96.6%
Total harmonic distortion <5%
Topology Isolated HF transformer
Mechanical & Environmental
Dimensions (H × W × D) 212 mm × 175 mm × 30.2 mm (excl. mounting brackets)
Weight (with mounting plate) 1.1 kg
Ambient temperature range -40°C to +65°C
IP rating Outdoor — IP67
Cooling Natural convection — no fans
DC connector Stäubli MC4 (integrated)
AC connector Enphase three-phase IQ Cable (Q-25-xx-3P variants)
Standards & Compliance
Grid compliance G98, G99, G100
Safety EN IEC 62109-1, EN IEC 62109-2
Product labelling CE
Limited warranty Up to 25 years (requires connected IQ Gateway)
Do IQ8AC microinverters themselves output three-phase power?
No. Each IQ8AC unit outputs single-phase 230 V L-N. The three-phase system is achieved by distributing units evenly across L1, L2, and L3 using the three-phase IQ Cable, which connects in sequence to each phase. The IQ Gateway monitors phase balance and can apply phase imbalance management (PIM) if required.
What IQ Cable do I need for a three-phase installation?
You need the three-phase IQ Cable variants — for example Q-25-17-3P-160 (for 72-cell landscape modules) or Q-25-10-3P-200 (for portrait orientation). These are four-conductor cables (L1, L2, L3, N) and include three-phase connector drops that the microinverters plug into. Three-phase field wireable connectors (Q-CONN-3P-10M / Q-CONN-3P-10F) are available for custom cable lengths.
How many IQ8AC units can I fit on one three-phase circuit?
A maximum of 30 IQ8AC units per three-phase 20A circuit (10 per phase), and a maximum of 18 units per three-phase IQ Cable section (6 per phase). Multiple circuits can be run from the same IQ Gateway.
Is G99 notification required for three-phase IQ8AC systems?
G99 applies to generation installations above 16 A per phase on a single-phase basis, or above 16 A per phase on three-phase. Given that 10 IQ8AC units per phase at 1.59 A = 15.9 A — close to the G98 threshold — most full three-phase circuit installations will require G99 notification. Always confirm with the DNO.
Does the IQ Gateway Metered support three-phase monitoring?
Yes. The IQ Gateway Metered (ENV-S-EM-230) supports three-phase consumption monitoring when paired with three CT clamps (one per phase). This enables generation, consumption, and export data to be tracked per phase and in total via the Enphase App and Installer Platform.
Enphase IQ8AC Microinverter 366W Three-Phase – 54 to 72 Cell, 366 VA Peak Power, MC4 Integrated | AIZO Quality Heating