Enphase IQ8AC Microinverter 366W
HomeStore

Enphase IQ8AC Microinverter 366W

Enphase IQ8AC Microinverter 366W

$74.50

Original: $212.85

-65%
Enphase IQ8AC Microinverter 366W

$212.85

$74.50

The Story

The Enphase IQ8AC Microinverter (model IQ8AC-72-M-INT) sits in the middle of the IQ8 Series range, delivering 366 W maximum AC output with a 97.3% peak efficiency (96.6% EU weighted). Designed for 54-cell to 72-cell modules (108 to 144 half-cell equivalents), it operates at 230 V / 50 Hz on a single phase and is compatible with both single-phase residential and three-phase commercial installations via the Enphase IQ Cable system. Integrated Stäubli MC4 DC connectors and the standard IQ8 form factor (212 mm × 175 mm × 30.2 mm, 1.1 kg) make it a direct upgrade path from IQ7 installations. CE marked, certified to G98, G99, and G100, and backed by an industry-leading 25-year limited warranty (with connected IQ Gateway). Source: UK datasheet DSH-00198-5.0, March 2026.

366 W
Max AC Output
97.3%
Peak Efficiency
96.6%
EU Weighted Efficiency
IP67
Enclosure Rating
25 Years
Limited Warranty
⚠ Installer Requirement: Requires Enphase IQ Cable for AC wiring. DC connection via integrated Stäubli MC4 connectors. A connected IQ Gateway is required for the 25-year warranty. G98/G99 DNO notification requirements must be met prior to energisation.
⚠ Module Pairing: The IQ8AC has a DC MPP window of 28–45 V and accepts modules with a maximum Isc of 20 A (with ×1.25 safety factor per IEC 62548) and a maximum DC voltage of 60 V. Verify panel compatibility at enphase.com/en-gb/installers/microinverters/calculator before specifying.
ℹ Positioning vs IQ8MC/IQ8HC: At 366 W AC output with 530 W max DC input, the IQ8AC is the optimum match for modules in the 350–450 W range that are now typical in new residential supply. The 28 V minimum MPP (vs 25 V for IQ8MC) better suits higher-Vmp 72-cell and half-cell panels.
530 W Max DC Input

The IQ8AC accepts up to 530 W DC input — 50 W more than the IQ8MC — allowing better matching to the 370–420 W modules widely shipped in 2024–25. The higher power ceiling reduces clipping losses at peak irradiance while still achieving a competitive DC/AC ratio under UK working conditions.

Optimal for 72-Cell Half-Cell Panels

The IQ8AC's 28–45 V MPP voltage range is well-aligned with the 30–38 V Vmp typical of 72-cell and 144 half-cell modules at UK operating temperatures. This keeps the microinverter in its highest-efficiency MPPT zone across the widest range of irradiance, delivering more annual kWh than a mismatched inverter would.

Module-Level Rapid Shutdown

Rapid shutdown is integral — each IQ8AC reduces its DC voltage immediately when the AC bus is de-energised by the IQ Gateway. No additional rooftop shutdown devices are needed, and the system complies with fire safety rapid shutdown requirements without any additional BOS cost.

Burst Mode for UK Weather

Enphase's patented Burst Mode keeps the IQ8AC generating at irradiance levels where competing inverters drop out. Under the frequent overcast conditions of UK summers, this low-light advantage is one of the most meaningful contributors to real-world annual yield above theoretical predictions.

Drop-In IQ7 Upgrade

The IQ8AC shares the same physical dimensions and mounting as the IQ7 Series (212 × 175 × 30.2 mm, same mounting plate). For retrofit upgrades or array expansions on existing IQ7 sites, the IQ8AC fits the same racking positions, uses the same IQ Cable, and connects to the existing IQ Gateway — reducing labour time and avoiding any racking modification.

Per-Panel Fault Isolation

Because each IQ8AC operates independently, a shading event, soiling, or fault on one panel has no impact on the output of neighbouring panels. This is the core advantage of microinverters over string inverters in real-world residential conditions, where at least some degree of inter-panel mismatch is almost always present.

Technical Specifications — IQ8AC-72-M-INT (UK Datasheet DSH-00198-5.0, March 2026)
DC Input
Typical module compatibility 54-cell/108 HC, 60-cell/120 HC, 66-cell/132 HC, 72-cell/144 HC
Min/Max input voltage 18 V / 60 V
Startup input voltage 22 V
Rated input voltage 36.5 V
Min/Max MPP voltage 28 V / 45 V
Max input current (Idcmax) 14 A
Max short-circuit input current (Iscmax) 25 A (max module Isc: 20 A, per IEC 62548 ×1.25)
Max input power (Pdcmax) 530 W
AC Output
Max AC output power 366 W
Max apparent power 360 VA
Rated power 360 W
Nominal grid voltage 230 V (range: 184–276 V)
Nominal frequency 50 Hz (range: 45–55 Hz)
Max output current 1.59 A
Max units per single-phase 20A circuit 10 (L+N)
Max units per three-phase 20A circuit 30 (3L+N)
Max units per IQ Cable section (single/multi-phase) 8 (L+N) / 18 (3L+N)
Power factor (adjustable) 0.8 leading … 0.8 lagging
Total harmonic distortion <5%
Peak efficiency 97.3%
EU weighted efficiency 96.6%
Topology Isolated HF transformer
Night-time power loss 50 mW
Mechanical & Environmental
Dimensions (H × W × D) 212 mm × 175 mm × 30.2 mm (excl. mounting brackets)
Weight (with mounting plate) 1.1 kg
Ambient temperature range -40°C to +65°C
Relative humidity 4–100% (condensing)
Cooling Natural convection — no fans
Enclosure Class II double-insulated, corrosion-resistant polymer
IP rating Outdoor — IP67
Max altitude < 2,600 m
DC connector Stäubli MC4 (integrated)
AC connector Enphase IQ Cable
Standards & Compliance
Grid compliance G98, G99, G100
Safety EN IEC 62109-1, EN IEC 62109-2
EMC EN IEC 61000-3-2/-3-3/-6-2/-6-3, EN IEC 50065-1/-2-2, EN 55011
Product labelling CE
Limited warranty Up to 25 years (requires connected IQ Gateway)
Communication PLC 110–120 kHz (Class B), narrowband 200 Hz
How does the IQ8AC differ from IQ8MC and IQ8HC?
Output power and MPP voltage range. IQ8MC: 330 W, MPP 25–45 V; IQ8AC: 366 W, MPP 28–45 V; IQ8HC: 384 W, MPP 29.5–45 V. The IQ8AC is the middle tier — more output than the MC, slightly lower minimum MPP voltage than the HC, best matched to 350–420 W modules with 30–38 V Vmp.
Can I mix IQ8AC and IQ8MC on the same system?
Yes — different IQ8 models can be mixed on the same IQ Gateway and IQ Cable branch. However, branch circuit sizing must be calculated on the highest-output model in the mix. IQ7 models can also coexist in Solar Only or grid-tied Solar + Battery configurations.
What is the maximum circuit size for single-phase with IQ8AC?
On a single-phase 20A circuit using 2.5 mm² IQ Cable, a maximum of 10 IQ8AC units can be connected per circuit (L+N), with a maximum of 8 per IQ Cable section when centre-feeding. For three-phase, up to 30 units per 20A circuit and 18 per IQ Cable section.
Does the IQ8AC work with IQ Battery 5P for self-consumption?
Yes. IQ8AC microinverters are fully compatible with the IQ Battery 5P in both Self-Consumption and (with IQ System Controller 3 INT) Full Backup configurations. The AC-coupled architecture means the battery connects to the consumer unit side, not to the microinverters directly.
Is G100 export limiting supported?
Yes. Power Export Limiting (PEL) for G100 compliance is supported as an advanced grid function, requiring an IQ Gateway Metered with correctly installed and oriented CT clamps. Configuration is done via the Enphase Installer Platform.
Enphase IQ8AC Microinverter 366W - Image 2

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

Enphase IQ8AC Microinverter 366W - Image 3

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

Enphase IQ8AC Microinverter 366W - Image 4

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

Description

The Enphase IQ8AC Microinverter (model IQ8AC-72-M-INT) sits in the middle of the IQ8 Series range, delivering 366 W maximum AC output with a 97.3% peak efficiency (96.6% EU weighted). Designed for 54-cell to 72-cell modules (108 to 144 half-cell equivalents), it operates at 230 V / 50 Hz on a single phase and is compatible with both single-phase residential and three-phase commercial installations via the Enphase IQ Cable system. Integrated Stäubli MC4 DC connectors and the standard IQ8 form factor (212 mm × 175 mm × 30.2 mm, 1.1 kg) make it a direct upgrade path from IQ7 installations. CE marked, certified to G98, G99, and G100, and backed by an industry-leading 25-year limited warranty (with connected IQ Gateway). Source: UK datasheet DSH-00198-5.0, March 2026.

366 W
Max AC Output
97.3%
Peak Efficiency
96.6%
EU Weighted Efficiency
IP67
Enclosure Rating
25 Years
Limited Warranty
⚠ Installer Requirement: Requires Enphase IQ Cable for AC wiring. DC connection via integrated Stäubli MC4 connectors. A connected IQ Gateway is required for the 25-year warranty. G98/G99 DNO notification requirements must be met prior to energisation.
⚠ Module Pairing: The IQ8AC has a DC MPP window of 28–45 V and accepts modules with a maximum Isc of 20 A (with ×1.25 safety factor per IEC 62548) and a maximum DC voltage of 60 V. Verify panel compatibility at enphase.com/en-gb/installers/microinverters/calculator before specifying.
ℹ Positioning vs IQ8MC/IQ8HC: At 366 W AC output with 530 W max DC input, the IQ8AC is the optimum match for modules in the 350–450 W range that are now typical in new residential supply. The 28 V minimum MPP (vs 25 V for IQ8MC) better suits higher-Vmp 72-cell and half-cell panels.
530 W Max DC Input

The IQ8AC accepts up to 530 W DC input — 50 W more than the IQ8MC — allowing better matching to the 370–420 W modules widely shipped in 2024–25. The higher power ceiling reduces clipping losses at peak irradiance while still achieving a competitive DC/AC ratio under UK working conditions.

Optimal for 72-Cell Half-Cell Panels

The IQ8AC's 28–45 V MPP voltage range is well-aligned with the 30–38 V Vmp typical of 72-cell and 144 half-cell modules at UK operating temperatures. This keeps the microinverter in its highest-efficiency MPPT zone across the widest range of irradiance, delivering more annual kWh than a mismatched inverter would.

Module-Level Rapid Shutdown

Rapid shutdown is integral — each IQ8AC reduces its DC voltage immediately when the AC bus is de-energised by the IQ Gateway. No additional rooftop shutdown devices are needed, and the system complies with fire safety rapid shutdown requirements without any additional BOS cost.

Burst Mode for UK Weather

Enphase's patented Burst Mode keeps the IQ8AC generating at irradiance levels where competing inverters drop out. Under the frequent overcast conditions of UK summers, this low-light advantage is one of the most meaningful contributors to real-world annual yield above theoretical predictions.

Drop-In IQ7 Upgrade

The IQ8AC shares the same physical dimensions and mounting as the IQ7 Series (212 × 175 × 30.2 mm, same mounting plate). For retrofit upgrades or array expansions on existing IQ7 sites, the IQ8AC fits the same racking positions, uses the same IQ Cable, and connects to the existing IQ Gateway — reducing labour time and avoiding any racking modification.

Per-Panel Fault Isolation

Because each IQ8AC operates independently, a shading event, soiling, or fault on one panel has no impact on the output of neighbouring panels. This is the core advantage of microinverters over string inverters in real-world residential conditions, where at least some degree of inter-panel mismatch is almost always present.

Technical Specifications — IQ8AC-72-M-INT (UK Datasheet DSH-00198-5.0, March 2026)
DC Input
Typical module compatibility 54-cell/108 HC, 60-cell/120 HC, 66-cell/132 HC, 72-cell/144 HC
Min/Max input voltage 18 V / 60 V
Startup input voltage 22 V
Rated input voltage 36.5 V
Min/Max MPP voltage 28 V / 45 V
Max input current (Idcmax) 14 A
Max short-circuit input current (Iscmax) 25 A (max module Isc: 20 A, per IEC 62548 ×1.25)
Max input power (Pdcmax) 530 W
AC Output
Max AC output power 366 W
Max apparent power 360 VA
Rated power 360 W
Nominal grid voltage 230 V (range: 184–276 V)
Nominal frequency 50 Hz (range: 45–55 Hz)
Max output current 1.59 A
Max units per single-phase 20A circuit 10 (L+N)
Max units per three-phase 20A circuit 30 (3L+N)
Max units per IQ Cable section (single/multi-phase) 8 (L+N) / 18 (3L+N)
Power factor (adjustable) 0.8 leading … 0.8 lagging
Total harmonic distortion <5%
Peak efficiency 97.3%
EU weighted efficiency 96.6%
Topology Isolated HF transformer
Night-time power loss 50 mW
Mechanical & Environmental
Dimensions (H × W × D) 212 mm × 175 mm × 30.2 mm (excl. mounting brackets)
Weight (with mounting plate) 1.1 kg
Ambient temperature range -40°C to +65°C
Relative humidity 4–100% (condensing)
Cooling Natural convection — no fans
Enclosure Class II double-insulated, corrosion-resistant polymer
IP rating Outdoor — IP67
Max altitude < 2,600 m
DC connector Stäubli MC4 (integrated)
AC connector Enphase IQ Cable
Standards & Compliance
Grid compliance G98, G99, G100
Safety EN IEC 62109-1, EN IEC 62109-2
EMC EN IEC 61000-3-2/-3-3/-6-2/-6-3, EN IEC 50065-1/-2-2, EN 55011
Product labelling CE
Limited warranty Up to 25 years (requires connected IQ Gateway)
Communication PLC 110–120 kHz (Class B), narrowband 200 Hz
How does the IQ8AC differ from IQ8MC and IQ8HC?
Output power and MPP voltage range. IQ8MC: 330 W, MPP 25–45 V; IQ8AC: 366 W, MPP 28–45 V; IQ8HC: 384 W, MPP 29.5–45 V. The IQ8AC is the middle tier — more output than the MC, slightly lower minimum MPP voltage than the HC, best matched to 350–420 W modules with 30–38 V Vmp.
Can I mix IQ8AC and IQ8MC on the same system?
Yes — different IQ8 models can be mixed on the same IQ Gateway and IQ Cable branch. However, branch circuit sizing must be calculated on the highest-output model in the mix. IQ7 models can also coexist in Solar Only or grid-tied Solar + Battery configurations.
What is the maximum circuit size for single-phase with IQ8AC?
On a single-phase 20A circuit using 2.5 mm² IQ Cable, a maximum of 10 IQ8AC units can be connected per circuit (L+N), with a maximum of 8 per IQ Cable section when centre-feeding. For three-phase, up to 30 units per 20A circuit and 18 per IQ Cable section.
Does the IQ8AC work with IQ Battery 5P for self-consumption?
Yes. IQ8AC microinverters are fully compatible with the IQ Battery 5P in both Self-Consumption and (with IQ System Controller 3 INT) Full Backup configurations. The AC-coupled architecture means the battery connects to the consumer unit side, not to the microinverters directly.
Is G100 export limiting supported?
Yes. Power Export Limiting (PEL) for G100 compliance is supported as an advanced grid function, requiring an IQ Gateway Metered with correctly installed and oriented CT clamps. Configuration is done via the Enphase Installer Platform.
Enphase IQ8AC Microinverter 366W | AIZO Quality Heating