EHC 14.4kW Comet PV Electric Boiler & 200L Pre-Plumbed Cylinder
HomeStore

EHC 14.4kW Comet PV Electric Boiler & 200L Pre-Plumbed Cylinder

EHC 14.4kW Comet PV Electric Boiler & 200L Pre-Plumbed Cylinder

$1,353.64

Original: $3,867.53

-65%
EHC 14.4kW Comet PV Electric Boiler & 200L Pre-Plumbed Cylinder

$3,867.53

$1,353.64

The Story

The EHC Comet PV 14.4kW Electric Boiler & 200L Pre-Plumbed Cylinder Package (EHCEPV14.4/200PPC) combines the field-configurable Comet PV multi-output boiler with a factory pre-plumbed 200-litre Neptune Indirect Unvented Stainless Steel Cylinder. The cylinder arrives with its valves, wiring centre, and circulating pump pre-fitted, cutting on-site installation time versus a standard indirect cylinder, while the boiler's coil-heated indirect recovery still gives faster reheat than a Direct cylinder.

14.4kW
Max Boiler Output
200L
Pre-Plumbed Cylinder
3kW
Backup Immersion Heater
240V 1N~
Single Phase Supply
2 Yr / 25 Yr
Boiler / Cylinder Vessel Warranty
20–85°C
Boiler Flow Temperature Range

Qualified Installation Required

This boiler must be installed, commissioned, and electrically connected by a qualified electrician in accordance with BS7671. The unvented cylinder is a controlled service under Building Regulation G3 (England & Wales), Technical Standard P3 (Scotland), or Building Regulation Part F (Northern Ireland) and must only be fitted by a competent, G3-qualified installer. A magnetic filter must be fitted to the boiler — failure to do so will invalidate the manufacturer's warranty.

Pre-Plumbed for Faster Installation

The cylinder's automatic by-pass, wiring centre, combination valve, temperature and pressure relief valve, tundish, twin 2-port zone valves, filling loop, and high-efficiency circulating pump are pre-fitted and pre-wired at the factory. EHC estimate this can save up to 70% of installation time on the cylinder side compared with a standard (non pre-plumbed) indirect cylinder fitted with loose components.

Model-Specific Cylinder Performance Data Not Published

EHC's current documentation confirms this pre-plumbed cylinder's capacity (200L) and cased dimensions (1120mm height x 710mm diameter), but does not publish model-specific coil surface area, heat-up time, or weight figures for this exact SKU. Confirm these directly with EHC if required for a design calculation.

Field-Configurable Output

A single boiler chassis covers 7.2, 9.6, 12.0, or 14.4kW via an on-board DIP switch, so installers can right-size the heat output to the building's calculated heat loss without stocking multiple boiler models.

Pre-Wired Cylinder Controls

The cylinder's wiring centre, zone valves, and pump are pre-connected at the factory, reducing the electrical terminations an installer needs to make on site.

Faster DHW Recovery Than Direct

As an indirect cylinder heated via the boiler's primary coil, recovery is markedly quicker than an equivalent-size Direct (immersion-only) cylinder.

Weather Compensation

An outdoor temperature sensor (Tos) lets the boiler's controller adjust flow temperature to a selectable heating curve, reducing energy use during milder weather.

Automatic Anti-Legionella Cycle

A configurable disinfection routine raises cylinder temperature to a set point on a chosen day and time, addressing Legionella risk without manual intervention.

Backup Immersion Heating

The cylinder's 3kW Incoloy immersion element provides electric backup water heating independent of the boiler's primary circuit.

Boiler — General
Model / MPN EHCEPV14.4/200PPC
Boiler range Comet PV Model 2 (7.2 / 9.6 / 12.0 / 14.4kW, field-selectable)
Rated output (this package) 14.4kW
Boiler dimensions (H x W x D) 716 x 316 x 235mm
Boiler weight ≈20.5kg
Boiler connections G3/4" (inside thread)
Safety class IP22
Outlet flow temperature range 20 – 85°C
Max. medium temperature 100°C
Max. system pressure 0.3MPa (3 bar)
Min. system pressure 0.05MPa (0.5 bar)
Built-in expansion vessel 5 litres, 1.5 bar pre-charge
Boiler — Electrical
Rated voltage 240V 1N~ (single phase)
MCB rating 63A
Load current 60.0A
Min. power supply cable c.s.a.* 10mm²
Max. power supply cable c.s.a. 16mm²
Max. allowed network impedance 0.22Ω
RCD protection 30mA Residual Current Device required on supply
Cylinder — 200L Pre-Plumbed Indirect
Cylinder capacity 200 litres
Cased height 1120mm
Cased diameter 710mm
Construction Duplex stainless steel, TIG welded
Factory pressure test 15 bar
Insulation CFC- and HCFC-free polyurethane foam
Regulatory status Controlled service – England & Wales Building Reg. G3 / Scotland Technical Standard P3 / N. Ireland Building Reg. Part F
Max. inlet mains water pressure 12 bar
Operating pressure 3.0 bar
Expansion vessel charge pressure 3.0 bar
Expansion valve opening pressure 6.0 bar
Max. operating pressure 7.0 bar
T&P relief valve opening 7.0 bar
Immersion element 3kW, 240V, Incoloy
Pre-Plumbed Pack — Included Components
Controls Pre-wired wiring centre
Valves Combination valve, twin 2-port zone valves
Safety Temperature & pressure relief valve, tundish
Circulation High-efficiency circulating pump
Fill/vent Filling loop, automatic by-pass
Warranty
Boiler warranty 2 years parts & labour, subject to registration within 60 days and annual servicing
Cylinder warranty 2 years parts & labour from commissioning, subject to registration
Stainless steel inner vessel 25-year guarantee (domestic installations)

*Minimum permitted cable size; actual installation cable size must be calculated by a qualified electrician per BS7671, accounting for cable type and installation method.

What does "pre-plumbed" mean on this cylinder?
It means the automatic by-pass, wiring centre, combination valve, temperature and pressure relief valve, tundish, zone valves, filling loop, and circulating pump are already fitted and wired at the factory, rather than being sourced and fitted individually on site.
Can the boiler output be changed after installation?
Yes. The Comet PV Model 2 chassis is field-configurable between 7.2, 9.6, 12.0, and 14.4kW using the on-board DIP switches and the boiler's on-screen configuration menu.
How does this compare with the Direct cylinder package?
This Pre-Plumbed cylinder is heated primarily via a coil connected to the boiler's primary circuit, giving faster recovery than a Direct (immersion-only) cylinder, with the added benefit of reduced on-site plumbing and wiring.
Does the pre-plumbed cylinder still need a qualified installer?
Yes. Although pre-plumbing reduces on-site work, the cylinder remains a controlled service under Building Regulation G3 (England & Wales) or equivalent, and must be installed and commissioned by a competent person.
Is a magnetic filter included?
No. A magnetic filter is not included but is a mandatory fit on all Comet PV boiler installations — omitting one will invalidate the manufacturer's boiler warranty.
EHC 14.4kW Comet PV Electric Boiler & 200L Pre-Plumbed Cylinder - Image 2

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

EHC 14.4kW Comet PV Electric Boiler & 200L Pre-Plumbed Cylinder - Image 3

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

EHC 14.4kW Comet PV Electric Boiler & 200L Pre-Plumbed Cylinder - Image 4

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

Description

The EHC Comet PV 14.4kW Electric Boiler & 200L Pre-Plumbed Cylinder Package (EHCEPV14.4/200PPC) combines the field-configurable Comet PV multi-output boiler with a factory pre-plumbed 200-litre Neptune Indirect Unvented Stainless Steel Cylinder. The cylinder arrives with its valves, wiring centre, and circulating pump pre-fitted, cutting on-site installation time versus a standard indirect cylinder, while the boiler's coil-heated indirect recovery still gives faster reheat than a Direct cylinder.

14.4kW
Max Boiler Output
200L
Pre-Plumbed Cylinder
3kW
Backup Immersion Heater
240V 1N~
Single Phase Supply
2 Yr / 25 Yr
Boiler / Cylinder Vessel Warranty
20–85°C
Boiler Flow Temperature Range

Qualified Installation Required

This boiler must be installed, commissioned, and electrically connected by a qualified electrician in accordance with BS7671. The unvented cylinder is a controlled service under Building Regulation G3 (England & Wales), Technical Standard P3 (Scotland), or Building Regulation Part F (Northern Ireland) and must only be fitted by a competent, G3-qualified installer. A magnetic filter must be fitted to the boiler — failure to do so will invalidate the manufacturer's warranty.

Pre-Plumbed for Faster Installation

The cylinder's automatic by-pass, wiring centre, combination valve, temperature and pressure relief valve, tundish, twin 2-port zone valves, filling loop, and high-efficiency circulating pump are pre-fitted and pre-wired at the factory. EHC estimate this can save up to 70% of installation time on the cylinder side compared with a standard (non pre-plumbed) indirect cylinder fitted with loose components.

Model-Specific Cylinder Performance Data Not Published

EHC's current documentation confirms this pre-plumbed cylinder's capacity (200L) and cased dimensions (1120mm height x 710mm diameter), but does not publish model-specific coil surface area, heat-up time, or weight figures for this exact SKU. Confirm these directly with EHC if required for a design calculation.

Field-Configurable Output

A single boiler chassis covers 7.2, 9.6, 12.0, or 14.4kW via an on-board DIP switch, so installers can right-size the heat output to the building's calculated heat loss without stocking multiple boiler models.

Pre-Wired Cylinder Controls

The cylinder's wiring centre, zone valves, and pump are pre-connected at the factory, reducing the electrical terminations an installer needs to make on site.

Faster DHW Recovery Than Direct

As an indirect cylinder heated via the boiler's primary coil, recovery is markedly quicker than an equivalent-size Direct (immersion-only) cylinder.

Weather Compensation

An outdoor temperature sensor (Tos) lets the boiler's controller adjust flow temperature to a selectable heating curve, reducing energy use during milder weather.

Automatic Anti-Legionella Cycle

A configurable disinfection routine raises cylinder temperature to a set point on a chosen day and time, addressing Legionella risk without manual intervention.

Backup Immersion Heating

The cylinder's 3kW Incoloy immersion element provides electric backup water heating independent of the boiler's primary circuit.

Boiler — General
Model / MPN EHCEPV14.4/200PPC
Boiler range Comet PV Model 2 (7.2 / 9.6 / 12.0 / 14.4kW, field-selectable)
Rated output (this package) 14.4kW
Boiler dimensions (H x W x D) 716 x 316 x 235mm
Boiler weight ≈20.5kg
Boiler connections G3/4" (inside thread)
Safety class IP22
Outlet flow temperature range 20 – 85°C
Max. medium temperature 100°C
Max. system pressure 0.3MPa (3 bar)
Min. system pressure 0.05MPa (0.5 bar)
Built-in expansion vessel 5 litres, 1.5 bar pre-charge
Boiler — Electrical
Rated voltage 240V 1N~ (single phase)
MCB rating 63A
Load current 60.0A
Min. power supply cable c.s.a.* 10mm²
Max. power supply cable c.s.a. 16mm²
Max. allowed network impedance 0.22Ω
RCD protection 30mA Residual Current Device required on supply
Cylinder — 200L Pre-Plumbed Indirect
Cylinder capacity 200 litres
Cased height 1120mm
Cased diameter 710mm
Construction Duplex stainless steel, TIG welded
Factory pressure test 15 bar
Insulation CFC- and HCFC-free polyurethane foam
Regulatory status Controlled service – England & Wales Building Reg. G3 / Scotland Technical Standard P3 / N. Ireland Building Reg. Part F
Max. inlet mains water pressure 12 bar
Operating pressure 3.0 bar
Expansion vessel charge pressure 3.0 bar
Expansion valve opening pressure 6.0 bar
Max. operating pressure 7.0 bar
T&P relief valve opening 7.0 bar
Immersion element 3kW, 240V, Incoloy
Pre-Plumbed Pack — Included Components
Controls Pre-wired wiring centre
Valves Combination valve, twin 2-port zone valves
Safety Temperature & pressure relief valve, tundish
Circulation High-efficiency circulating pump
Fill/vent Filling loop, automatic by-pass
Warranty
Boiler warranty 2 years parts & labour, subject to registration within 60 days and annual servicing
Cylinder warranty 2 years parts & labour from commissioning, subject to registration
Stainless steel inner vessel 25-year guarantee (domestic installations)

*Minimum permitted cable size; actual installation cable size must be calculated by a qualified electrician per BS7671, accounting for cable type and installation method.

What does "pre-plumbed" mean on this cylinder?
It means the automatic by-pass, wiring centre, combination valve, temperature and pressure relief valve, tundish, zone valves, filling loop, and circulating pump are already fitted and wired at the factory, rather than being sourced and fitted individually on site.
Can the boiler output be changed after installation?
Yes. The Comet PV Model 2 chassis is field-configurable between 7.2, 9.6, 12.0, and 14.4kW using the on-board DIP switches and the boiler's on-screen configuration menu.
How does this compare with the Direct cylinder package?
This Pre-Plumbed cylinder is heated primarily via a coil connected to the boiler's primary circuit, giving faster recovery than a Direct (immersion-only) cylinder, with the added benefit of reduced on-site plumbing and wiring.
Does the pre-plumbed cylinder still need a qualified installer?
Yes. Although pre-plumbing reduces on-site work, the cylinder remains a controlled service under Building Regulation G3 (England & Wales) or equivalent, and must be installed and commissioned by a competent person.
Is a magnetic filter included?
No. A magnetic filter is not included but is a mandatory fit on all Comet PV boiler installations — omitting one will invalidate the manufacturer's boiler warranty.
EHC 14.4kW Comet PV Electric Boiler & 200L Pre-Plumbed Cylinder | AIZO Quality Heating