EHC 12kW Slimjim Electric Flow Boiler & 200L Pre-Plumbed Cylinder
HomeStore

EHC 12kW Slimjim Electric Flow Boiler & 200L Pre-Plumbed Cylinder

EHC 12kW Slimjim Electric Flow Boiler & 200L Pre-Plumbed Cylinder

$1,348.48

Original: $3,852.80

-65%
EHC 12kW Slimjim Electric Flow Boiler & 200L Pre-Plumbed Cylinder

$3,852.80

$1,348.48

The Story

The EHC 12kW SlimJim Electric Flow Boiler & 200L Pre-Plumbed Cylinder Package (EHCSJ12/200PPC) combines the compact 12kW SlimJim electric flow boiler with a factory pre-plumbed 200-litre Neptune Indirect Unvented Stainless Steel Cylinder. The cylinder arrives with its controls, valves, and circulating pump already fitted and wired, cutting on-site installation time versus a standard (non-pre-plumbed) indirect cylinder package.

12kW
Boiler Output
200L
Pre-Plumbed Cylinder
100%
Boiler Efficiency (No Flue)
240V 1ph
Electrical Supply
30–80°C
Boiler Flow Temperature
2 Yr / 25 Yr
Boiler / Cylinder Vessel Warranty

Qualified Installation & Load Check Required

This boiler must be installed and electrically connected by a qualified electrician in accordance with BS7671. A load check must be carried out before installation, as the boiler draws 50.0A and the property's incoming supply may need upgrading. The supply must be protected at the meter position with a 30mA double-pole RCD (minimum 3mm contact separation) and a suitably rated MCB. A magnetic filter must be fitted to the return pipework before the circulation pump — failure to clean it annually may result in boiler or system failure and will affect warranty cover.

Pre-Plumbed for Faster Fit

The cylinder's automatic by-pass, wiring centre, combination valve, temperature and pressure relief valve, tundish, twin 2-port zone valves, filling loop, and high-efficiency circulating pump are pre-fitted and pre-wired at the factory. EHC estimate this can save up to 70% of installation time on the cylinder side compared with a standard indirect cylinder fitted with loose components.

Model-Specific Cylinder Performance Data Not Published

EHC's current documentation confirms the 200L capacity and 1120mm x 710mm cased dimensions of the pre-plumbed cylinder used in this package, but does not publish model-specific coil surface area, heat-up time, or weight figures. Confirm these directly with EHC if required for a design calculation.

Compact Flow Boiler Footprint

At 912 x 203 x 172mm, the SlimJim boiler is designed to maximise cupboard space, with an easy-fit front cover for future maintenance access.

Pre-Wired Cylinder Controls

The cylinder's wiring centre, zone valves, and pump are pre-connected at the factory, reducing the electrical terminations an installer needs to make on site.

Three-Stage Output Control

On-board dip switches allow the boiler's rated output to be staged down, giving some flexibility to match the installed heat load.

High-Current Safety Cut-Out

A dedicated WT3 safety thermal cut-out disconnects the boiler if internal temperature reaches approximately 100°C, protecting the heat exchanger.

Faster DHW Recovery Than Direct

As an indirect cylinder heated via the boiler's primary coil, recovery is markedly quicker than an equivalent-size direct (immersion-only) cylinder.

No Flue, No Combustion Byproducts

As a fully electric flow boiler, the SlimJim requires no flue, no gas supply, and no annual gas safety check.

Boiler — 12kW SlimJim (General)
Model / MPN EHCSJ12/200PPC
Boiler chassis SlimJim Electric Flow Boiler
Boiler dimensions (H x W x D) 912 x 203 x 172mm
Boiler weight ≈11kg
Boiler connections 22mm compression (flow top, return bottom)
Safety class IP22
Outflow water temperature range 30 – 80°C
Max. water temperature 100°C
Overheat protection cut-out 100°C
Max. system pressure 3 bar
Min. system pressure 0.5 bar
Boiler — 12kW SlimJim (Electrical)
Electrical supply 240V 1ph 50Hz
Load current 50.0A
Minimum permitted cable diameter* 10mm²
Recommended protection (MCB) 63A
Max. allowed network impedance 0.24Ω
Heat output 40,946 BTU/h
ErP rating D
Cylinder — 200L Pre-Plumbed Indirect
Cylinder capacity 200 litres
Cased height 1120mm
Cased diameter 710mm
Construction Duplex stainless steel, TIG welded
Factory pressure test 15 bar
Insulation CFC- and HCFC-free polyurethane foam
Regulatory status Controlled service – England & Wales Building Reg. G3 / Scotland Technical Standard P3 / N. Ireland Building Reg. Part F
Max. inlet mains water pressure 12 bar
Operating pressure 3.0 bar
Expansion vessel charge pressure 3.0 bar
Expansion valve opening pressure 6.0 bar
Max. operating pressure 7.0 bar
T&P relief valve opening 7.0 bar
Immersion element 3kW, 240V, Incoloy
Immersion electrical supply Dedicated 240V circuit, fused per element
Pre-Plumbed Pack — Included Components
Controls Pre-wired wiring centre
Valves Combination valve, twin 2-port zone valves
Safety Temperature & pressure relief valve, tundish
Circulation High-efficiency circulating pump
Fill/vent Filling loop, automatic by-pass
Warranty
Boiler warranty 2 years parts & labour, subject to registration and annual servicing
Cylinder warranty 2 years parts & labour from commissioning, subject to registration
Stainless steel inner vessel 25-year guarantee (domestic installations)

*Minimum permitted cable size; actual installation cable size must be calculated by a qualified electrician per BS7671, accounting for cable type and installation method.

What's the difference between this and the standard 200L Indirect package?
This package uses the pre-plumbed version of the 200L Neptune Indirect cylinder, which arrives with its valves, wiring centre, and circulating pump already factory-fitted, reducing on-site plumbing and wiring work compared with the standard indirect cylinder package.
Does the pre-plumbed cylinder still need a qualified installer?
Yes. Although pre-plumbing reduces on-site work, the cylinder remains a controlled service under Building Regulation G3 (England & Wales) or equivalent, and must be installed and commissioned by a competent person.
What space does the SlimJim boiler need?
The boiler itself is 912 x 203 x 172mm; EHC recommend a minimum 400mm clearance in front for cover removal and 50mm clearance to either side for air flow.
Is a magnetic filter included?
A magnetic filter is required on the boiler's return pipework before the circulation pump; confirm inclusion within the specific pack contents at time of order.
Can the boiler output be reduced after installation?
Yes, the SlimJim's on-board dip switches allow the rated output to be staged down in increments to better match a calculated heat load.
EHC 12kW Slimjim Electric Flow Boiler & 200L Pre-Plumbed Cylinder - Image 2

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

EHC 12kW Slimjim Electric Flow Boiler & 200L Pre-Plumbed Cylinder - Image 3

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

EHC 12kW Slimjim Electric Flow Boiler & 200L Pre-Plumbed Cylinder - Image 4

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

Description

The EHC 12kW SlimJim Electric Flow Boiler & 200L Pre-Plumbed Cylinder Package (EHCSJ12/200PPC) combines the compact 12kW SlimJim electric flow boiler with a factory pre-plumbed 200-litre Neptune Indirect Unvented Stainless Steel Cylinder. The cylinder arrives with its controls, valves, and circulating pump already fitted and wired, cutting on-site installation time versus a standard (non-pre-plumbed) indirect cylinder package.

12kW
Boiler Output
200L
Pre-Plumbed Cylinder
100%
Boiler Efficiency (No Flue)
240V 1ph
Electrical Supply
30–80°C
Boiler Flow Temperature
2 Yr / 25 Yr
Boiler / Cylinder Vessel Warranty

Qualified Installation & Load Check Required

This boiler must be installed and electrically connected by a qualified electrician in accordance with BS7671. A load check must be carried out before installation, as the boiler draws 50.0A and the property's incoming supply may need upgrading. The supply must be protected at the meter position with a 30mA double-pole RCD (minimum 3mm contact separation) and a suitably rated MCB. A magnetic filter must be fitted to the return pipework before the circulation pump — failure to clean it annually may result in boiler or system failure and will affect warranty cover.

Pre-Plumbed for Faster Fit

The cylinder's automatic by-pass, wiring centre, combination valve, temperature and pressure relief valve, tundish, twin 2-port zone valves, filling loop, and high-efficiency circulating pump are pre-fitted and pre-wired at the factory. EHC estimate this can save up to 70% of installation time on the cylinder side compared with a standard indirect cylinder fitted with loose components.

Model-Specific Cylinder Performance Data Not Published

EHC's current documentation confirms the 200L capacity and 1120mm x 710mm cased dimensions of the pre-plumbed cylinder used in this package, but does not publish model-specific coil surface area, heat-up time, or weight figures. Confirm these directly with EHC if required for a design calculation.

Compact Flow Boiler Footprint

At 912 x 203 x 172mm, the SlimJim boiler is designed to maximise cupboard space, with an easy-fit front cover for future maintenance access.

Pre-Wired Cylinder Controls

The cylinder's wiring centre, zone valves, and pump are pre-connected at the factory, reducing the electrical terminations an installer needs to make on site.

Three-Stage Output Control

On-board dip switches allow the boiler's rated output to be staged down, giving some flexibility to match the installed heat load.

High-Current Safety Cut-Out

A dedicated WT3 safety thermal cut-out disconnects the boiler if internal temperature reaches approximately 100°C, protecting the heat exchanger.

Faster DHW Recovery Than Direct

As an indirect cylinder heated via the boiler's primary coil, recovery is markedly quicker than an equivalent-size direct (immersion-only) cylinder.

No Flue, No Combustion Byproducts

As a fully electric flow boiler, the SlimJim requires no flue, no gas supply, and no annual gas safety check.

Boiler — 12kW SlimJim (General)
Model / MPN EHCSJ12/200PPC
Boiler chassis SlimJim Electric Flow Boiler
Boiler dimensions (H x W x D) 912 x 203 x 172mm
Boiler weight ≈11kg
Boiler connections 22mm compression (flow top, return bottom)
Safety class IP22
Outflow water temperature range 30 – 80°C
Max. water temperature 100°C
Overheat protection cut-out 100°C
Max. system pressure 3 bar
Min. system pressure 0.5 bar
Boiler — 12kW SlimJim (Electrical)
Electrical supply 240V 1ph 50Hz
Load current 50.0A
Minimum permitted cable diameter* 10mm²
Recommended protection (MCB) 63A
Max. allowed network impedance 0.24Ω
Heat output 40,946 BTU/h
ErP rating D
Cylinder — 200L Pre-Plumbed Indirect
Cylinder capacity 200 litres
Cased height 1120mm
Cased diameter 710mm
Construction Duplex stainless steel, TIG welded
Factory pressure test 15 bar
Insulation CFC- and HCFC-free polyurethane foam
Regulatory status Controlled service – England & Wales Building Reg. G3 / Scotland Technical Standard P3 / N. Ireland Building Reg. Part F
Max. inlet mains water pressure 12 bar
Operating pressure 3.0 bar
Expansion vessel charge pressure 3.0 bar
Expansion valve opening pressure 6.0 bar
Max. operating pressure 7.0 bar
T&P relief valve opening 7.0 bar
Immersion element 3kW, 240V, Incoloy
Immersion electrical supply Dedicated 240V circuit, fused per element
Pre-Plumbed Pack — Included Components
Controls Pre-wired wiring centre
Valves Combination valve, twin 2-port zone valves
Safety Temperature & pressure relief valve, tundish
Circulation High-efficiency circulating pump
Fill/vent Filling loop, automatic by-pass
Warranty
Boiler warranty 2 years parts & labour, subject to registration and annual servicing
Cylinder warranty 2 years parts & labour from commissioning, subject to registration
Stainless steel inner vessel 25-year guarantee (domestic installations)

*Minimum permitted cable size; actual installation cable size must be calculated by a qualified electrician per BS7671, accounting for cable type and installation method.

What's the difference between this and the standard 200L Indirect package?
This package uses the pre-plumbed version of the 200L Neptune Indirect cylinder, which arrives with its valves, wiring centre, and circulating pump already factory-fitted, reducing on-site plumbing and wiring work compared with the standard indirect cylinder package.
Does the pre-plumbed cylinder still need a qualified installer?
Yes. Although pre-plumbing reduces on-site work, the cylinder remains a controlled service under Building Regulation G3 (England & Wales) or equivalent, and must be installed and commissioned by a competent person.
What space does the SlimJim boiler need?
The boiler itself is 912 x 203 x 172mm; EHC recommend a minimum 400mm clearance in front for cover removal and 50mm clearance to either side for air flow.
Is a magnetic filter included?
A magnetic filter is required on the boiler's return pipework before the circulation pump; confirm inclusion within the specific pack contents at time of order.
Can the boiler output be reduced after installation?
Yes, the SlimJim's on-board dip switches allow the rated output to be staged down in increments to better match a calculated heat load.