Original: $4,827.38
-65%$4,827.38
$1,689.58The Story
The Samsung EHS Mono Gen6 is a fully-contained monoblock air-to-water heat pump in which the complete refrigerant circuit — inverter-driven BLDC twin-rotary compressor, plate heat exchanger, and electronic expansion valve — is housed entirely within the outdoor unit. Only insulated water pipes run indoors, eliminating any requirement for F-Gas work on the indoor side and simplifying compliance with Building Regulations. The AE120RXYDEG/EU delivers a rated heating capacity of 12 kW at standard A7/W35 test conditions, achieving a Seasonal COP (SCOP) of 4.69 at LWT 35°C — ErP class A+++ — and SCOP 3.51 at LWT 55°C (A++) per EN 14825. This makes it eligible for the UK Boiler Upgrade Scheme (BUS) when installed by an MCS-registered contractor. The unit operates reliably down to −25°C ambient and delivers flow temperatures up to 65°C, serving both low-temperature underfloor heating circuits and existing radiator systems. R32 refrigerant (GWP 675, ODP 0) reduces CO₂-equivalent emissions by 73% compared with R410A systems of equivalent capacity.
Capacity (A7/W35)
@ LWT 35°C
Operating Temp
Temperature
(Heating Mode)
⚠ Installer & Safety Critical
- F-Gas regulations apply. R32 is a fluorinated greenhouse gas (GWP 675). All installation, commissioning, and decommissioning work must be carried out by an F-Gas certified engineer. Refrigerant site records must be maintained.
- No integral pressure relief valve. The outdoor unit does not include a PRV. A compliant pressure relief valve must be installed in the hydraulic circuit in accordance with BS EN 12828 and Building Regulations Part G.
- MCS registration required for BUS grant. The unit and installation must be registered by an MCS-certified installer before the Boiler Upgrade Scheme grant is submitted.
- Minimum system water volume: 50 litres. The installer must calculate total hydraulic circuit volume and add a buffer vessel if the minimum cannot be met from pipework and cylinder coil volume alone.
⚠ Compatibility & Advisory
- Control module not included. The outdoor unit requires the Samsung MIM-E03CN control module (which includes Touch Controller MWR-WW10N) to operate. Order separately or as part of a ClimateHub package.
- Wi-Fi not embedded. SmartThings App connectivity requires the optional MIM-H04N Wi-Fi Kit (sold separately).
- Dedicated electrical circuit required: 35 A MCB. This unit draws MCA 28.0 A / MFA 35.0 A. Confirm available supply capacity and cable sizing to MCA before specifying.
- Filter/strainer mandatory on the return water pipe to protect the outdoor unit heat exchanger from system debris. Clean regularly to maintain minimum flow rate.
ⓘ Product Highlights
- MCS Listed — qualifies for the UK Boiler Upgrade Scheme (BUS) £7,500 grant when installed by an MCS-certified contractor.
- Compatible with the Samsung ClimateHub tank-integrated hydro unit (200 L or 260 L) or third-party cylinders and control kits from various manufacturers.
- 2-Zone Control supported — optimise a high-temperature radiator zone and a low-temperature underfloor heating zone independently from a single outdoor unit.
- PV-Enabled & Smart Grid Ready — shifts electrical demand to periods of solar surplus or off-peak grid tariffs to minimise running costs.
Key Features
True Monoblock Architecture
Unlike a split heat pump, the EHS Mono houses the complete refrigerant circuit outdoors. No refrigerant pipework penetrates the building envelope — only insulated water pipes connect the outdoor unit to the indoor hydraulic system. This eliminates F-Gas work on the indoor side, broadens compatibility with third-party cylinders and control kits, and simplifies compliance with Building Regulations Part F.
SCOP 4.69 — ErP A+++ at LWT 35°C
Tested across a full seasonal load profile per EN 14825, this unit achieves SCOP 4.69 at a 35°C leaving water temperature — the ideal operating point for underfloor heating systems. At 55°C flow (for legacy radiator retrofits) the SCOP is 3.51 (A++), still considerably better than a condensing boiler. The inverter-driven compressor modulates continuously to match heat demand, avoiding on/off cycling losses and reducing wear.
−25°C Cold-Climate Performance
The unit maintains full rated output down to −7°C ambient (A−7/W35 peak condition: 12.0 kW) and continues to operate down to −25°C through compressor modulation and supplementary backup heating. Domestic hot water mode remains available down to −25°C, covering the entire range of UK winter conditions with confidence.
Up to 65°C Flow Temperature
A maximum leaving water temperature of 65°C allows this unit to serve legacy radiator systems without mandatory full system re-sizing, provided heat-loss calculations confirm adequate emitter output at the specified flow temperature. For maximum efficiency, the system is best designed to run at 45–55°C or lower, where the SCOP improvement over boiler operation is most significant.
Anti-Salt Heat Exchanger & Robust Casing
The louvred-fin heat exchanger uses G-Fin geometry with an Anti-Salt coating on fins and tubes to resist corrosion in coastal or industrially polluted environments. The powder-coated electro-galvanised steel casing in Samsung's Earth Brown finish provides additional weathering protection. Two axial-flow fans with BLDC motors (2 × 125 W) deliver 99 m³/min airflow at 650 rpm for high throughput with low electrical draw.
Smart Connectivity & Energy Management
Via the optional MIM-H04N Wi-Fi Kit, the unit integrates with the Samsung SmartThings ecosystem for remote on/off, scheduling, and energy monitoring from iOS or Android. The Touch Controller MWR-WW10N (included with MIM-E03CN) supports 2-Zone temperature scheduling, error monitoring, and summer-mode cooling. Smart Grid Ready and PV-Enabled logic allow demand shifting toward off-peak tariffs or surplus solar generation.
Technical Specifications
| Parameter | AE120RXYDEG/EU |
|---|---|
| General | |
| Model Number | AE120RXYDEG/EU |
| Series | EHS Mono Gen6 |
| Type | Monoblock Air-to-Water Heat Pump (A2W) |
| Power Supply | 1-phase, 220–240 V, 50 Hz |
| Refrigerant | R32 (GWP 675, ODP 0) — fluorinated greenhouse gas |
| Refrigerant Charge | 2.20 kg / 1.49 tCO₂e |
| Refrigerant Control | Electronic Expansion Valve (EEV) |
| Heating Performance | |
| Rated Heating Capacity (A7/W35) | 12 kW |
| Heating Power Input (A7/W35) | 2,650 W |
| COP (A7/W35) | 4.53 |
| Heating Capacity at A2/W35 (2°C ambient) | 10.8 kW |
| Heating Capacity at A−7/W35 (Peak, −7°C) | 12.0 kW |
| PdesignH at LWT 35°C | 13.0 kW |
| PdesignH at LWT 55°C | 12.0 kW |
| Cooling Performance | |
| Rated Cooling Capacity (A7/W35) | 12 kW |
| Cooling Power Input (A7/W35) | 2,770 W |
| EER (A7/W35) | 4.33 |
| Seasonal Efficiency (EN 14825) | |
| SCOP at LWT 35°C | 4.69 — ErP Class A+++ |
| SCOP at LWT 55°C | 3.51 — ErP Class A++ |
| SEER (Cooling) | 5.22 |
| Electrical | |
| Current Input — Cooling | 13.2 A |
| Current Input — Heating | 12.2 A |
| Minimum Circuit Ampacity (MCA) | 28.0 A |
| Maximum Fuse Ampacity (MFA) | 35.0 A |
| Hydraulics | |
| Leaving Water Temp — Heating Range | 15–65°C |
| Leaving Water Temp — Cooling Range | 5–25°C |
| Nominal Water Flow Rate (H/C) | 34.6 / 34.6 LPM (H/C) |
| Minimum Water Flow Rate | 12.0 LPM |
| Maximum Water Flow Rate | 58.0 LPM |
| Maximum System Water Pressure | 3 bar |
| Water Pipe Connections | BSPP Male 1″ (inlet & outlet) |
| Minimum System Water Volume | 50 litres (buffer vessel recommended if not achieved) |
| Operating Conditions | |
| Heating Ambient Range | −25°C to +35°C |
| Cooling Ambient Range | +10°C to +46°C |
| Domestic Hot Water Ambient Range | −25°C to +43°C |
| Airside & Heat Exchanger | |
| Air Flow Rate | 99 m³/min |
| Fan Quantity / Type | 2 × Axial Propeller, Brushless DC Motor |
| Fan Motor Output | 2 × 125 W |
| Fan Speed | 650 rpm |
| Fan Discharge Direction | Horizontal |
| Heat Exchanger Fin Type | G-Fin Louvred |
| Heat Exchanger Tube Diameter | Φ7.94 mm, 2-row |
| Fin/Coil Treatment | Anti-Salt coating |
| Acoustics (ISO 3741) | |
| Sound Pressure Level — Heating Mode | 50 dB(A) |
| Sound Power Level — Heating Mode | 64 dB(A) |
| Sound Pressure Level — Cooling Mode | 50 dB(A) |
| Sound Power Level — Cooling Mode | 65 dB(A) |
| Compressor | |
| Compressor Type | BLDC Twin Rotary, Inverter Driven |
| Compressor Oil Type / Initial Charge | POE / 1,700 cc |
| Physical | |
| Net Dimensions (W × H × D) | 940 × 1,420 × 330 mm |
| Net Weight | 110.0 kg |
| Casing Material | Powder-coated electro-galvanised steel |
| Casing Colour | Earth Brown |
| Controls & Connectivity | |
| Control Module (required, sold separately) | MIM-E03CN (incl. Touch Controller MWR-WW10N) |
| Wi-Fi Connectivity | Optional — MIM-H04N Wi-Fi Kit (sold separately) |
| SmartThings App Compatible | Yes (requires MIM-H04N) |
| 2-Zone Control | Yes |
| PV-Enabled | Yes |
| Smart Grid Ready | Yes |
Frequently Asked Questions

Details & Craftsmanship
Every detail has been carefully considered to bring you the perfect product.
Description
The Samsung EHS Mono Gen6 is a fully-contained monoblock air-to-water heat pump in which the complete refrigerant circuit — inverter-driven BLDC twin-rotary compressor, plate heat exchanger, and electronic expansion valve — is housed entirely within the outdoor unit. Only insulated water pipes run indoors, eliminating any requirement for F-Gas work on the indoor side and simplifying compliance with Building Regulations. The AE120RXYDEG/EU delivers a rated heating capacity of 12 kW at standard A7/W35 test conditions, achieving a Seasonal COP (SCOP) of 4.69 at LWT 35°C — ErP class A+++ — and SCOP 3.51 at LWT 55°C (A++) per EN 14825. This makes it eligible for the UK Boiler Upgrade Scheme (BUS) when installed by an MCS-registered contractor. The unit operates reliably down to −25°C ambient and delivers flow temperatures up to 65°C, serving both low-temperature underfloor heating circuits and existing radiator systems. R32 refrigerant (GWP 675, ODP 0) reduces CO₂-equivalent emissions by 73% compared with R410A systems of equivalent capacity.
Capacity (A7/W35)
@ LWT 35°C
Operating Temp
Temperature
(Heating Mode)
⚠ Installer & Safety Critical
- F-Gas regulations apply. R32 is a fluorinated greenhouse gas (GWP 675). All installation, commissioning, and decommissioning work must be carried out by an F-Gas certified engineer. Refrigerant site records must be maintained.
- No integral pressure relief valve. The outdoor unit does not include a PRV. A compliant pressure relief valve must be installed in the hydraulic circuit in accordance with BS EN 12828 and Building Regulations Part G.
- MCS registration required for BUS grant. The unit and installation must be registered by an MCS-certified installer before the Boiler Upgrade Scheme grant is submitted.
- Minimum system water volume: 50 litres. The installer must calculate total hydraulic circuit volume and add a buffer vessel if the minimum cannot be met from pipework and cylinder coil volume alone.
⚠ Compatibility & Advisory
- Control module not included. The outdoor unit requires the Samsung MIM-E03CN control module (which includes Touch Controller MWR-WW10N) to operate. Order separately or as part of a ClimateHub package.
- Wi-Fi not embedded. SmartThings App connectivity requires the optional MIM-H04N Wi-Fi Kit (sold separately).
- Dedicated electrical circuit required: 35 A MCB. This unit draws MCA 28.0 A / MFA 35.0 A. Confirm available supply capacity and cable sizing to MCA before specifying.
- Filter/strainer mandatory on the return water pipe to protect the outdoor unit heat exchanger from system debris. Clean regularly to maintain minimum flow rate.
ⓘ Product Highlights
- MCS Listed — qualifies for the UK Boiler Upgrade Scheme (BUS) £7,500 grant when installed by an MCS-certified contractor.
- Compatible with the Samsung ClimateHub tank-integrated hydro unit (200 L or 260 L) or third-party cylinders and control kits from various manufacturers.
- 2-Zone Control supported — optimise a high-temperature radiator zone and a low-temperature underfloor heating zone independently from a single outdoor unit.
- PV-Enabled & Smart Grid Ready — shifts electrical demand to periods of solar surplus or off-peak grid tariffs to minimise running costs.
Key Features
True Monoblock Architecture
Unlike a split heat pump, the EHS Mono houses the complete refrigerant circuit outdoors. No refrigerant pipework penetrates the building envelope — only insulated water pipes connect the outdoor unit to the indoor hydraulic system. This eliminates F-Gas work on the indoor side, broadens compatibility with third-party cylinders and control kits, and simplifies compliance with Building Regulations Part F.
SCOP 4.69 — ErP A+++ at LWT 35°C
Tested across a full seasonal load profile per EN 14825, this unit achieves SCOP 4.69 at a 35°C leaving water temperature — the ideal operating point for underfloor heating systems. At 55°C flow (for legacy radiator retrofits) the SCOP is 3.51 (A++), still considerably better than a condensing boiler. The inverter-driven compressor modulates continuously to match heat demand, avoiding on/off cycling losses and reducing wear.
−25°C Cold-Climate Performance
The unit maintains full rated output down to −7°C ambient (A−7/W35 peak condition: 12.0 kW) and continues to operate down to −25°C through compressor modulation and supplementary backup heating. Domestic hot water mode remains available down to −25°C, covering the entire range of UK winter conditions with confidence.
Up to 65°C Flow Temperature
A maximum leaving water temperature of 65°C allows this unit to serve legacy radiator systems without mandatory full system re-sizing, provided heat-loss calculations confirm adequate emitter output at the specified flow temperature. For maximum efficiency, the system is best designed to run at 45–55°C or lower, where the SCOP improvement over boiler operation is most significant.
Anti-Salt Heat Exchanger & Robust Casing
The louvred-fin heat exchanger uses G-Fin geometry with an Anti-Salt coating on fins and tubes to resist corrosion in coastal or industrially polluted environments. The powder-coated electro-galvanised steel casing in Samsung's Earth Brown finish provides additional weathering protection. Two axial-flow fans with BLDC motors (2 × 125 W) deliver 99 m³/min airflow at 650 rpm for high throughput with low electrical draw.
Smart Connectivity & Energy Management
Via the optional MIM-H04N Wi-Fi Kit, the unit integrates with the Samsung SmartThings ecosystem for remote on/off, scheduling, and energy monitoring from iOS or Android. The Touch Controller MWR-WW10N (included with MIM-E03CN) supports 2-Zone temperature scheduling, error monitoring, and summer-mode cooling. Smart Grid Ready and PV-Enabled logic allow demand shifting toward off-peak tariffs or surplus solar generation.
Technical Specifications
| Parameter | AE120RXYDEG/EU |
|---|---|
| General | |
| Model Number | AE120RXYDEG/EU |
| Series | EHS Mono Gen6 |
| Type | Monoblock Air-to-Water Heat Pump (A2W) |
| Power Supply | 1-phase, 220–240 V, 50 Hz |
| Refrigerant | R32 (GWP 675, ODP 0) — fluorinated greenhouse gas |
| Refrigerant Charge | 2.20 kg / 1.49 tCO₂e |
| Refrigerant Control | Electronic Expansion Valve (EEV) |
| Heating Performance | |
| Rated Heating Capacity (A7/W35) | 12 kW |
| Heating Power Input (A7/W35) | 2,650 W |
| COP (A7/W35) | 4.53 |
| Heating Capacity at A2/W35 (2°C ambient) | 10.8 kW |
| Heating Capacity at A−7/W35 (Peak, −7°C) | 12.0 kW |
| PdesignH at LWT 35°C | 13.0 kW |
| PdesignH at LWT 55°C | 12.0 kW |
| Cooling Performance | |
| Rated Cooling Capacity (A7/W35) | 12 kW |
| Cooling Power Input (A7/W35) | 2,770 W |
| EER (A7/W35) | 4.33 |
| Seasonal Efficiency (EN 14825) | |
| SCOP at LWT 35°C | 4.69 — ErP Class A+++ |
| SCOP at LWT 55°C | 3.51 — ErP Class A++ |
| SEER (Cooling) | 5.22 |
| Electrical | |
| Current Input — Cooling | 13.2 A |
| Current Input — Heating | 12.2 A |
| Minimum Circuit Ampacity (MCA) | 28.0 A |
| Maximum Fuse Ampacity (MFA) | 35.0 A |
| Hydraulics | |
| Leaving Water Temp — Heating Range | 15–65°C |
| Leaving Water Temp — Cooling Range | 5–25°C |
| Nominal Water Flow Rate (H/C) | 34.6 / 34.6 LPM (H/C) |
| Minimum Water Flow Rate | 12.0 LPM |
| Maximum Water Flow Rate | 58.0 LPM |
| Maximum System Water Pressure | 3 bar |
| Water Pipe Connections | BSPP Male 1″ (inlet & outlet) |
| Minimum System Water Volume | 50 litres (buffer vessel recommended if not achieved) |
| Operating Conditions | |
| Heating Ambient Range | −25°C to +35°C |
| Cooling Ambient Range | +10°C to +46°C |
| Domestic Hot Water Ambient Range | −25°C to +43°C |
| Airside & Heat Exchanger | |
| Air Flow Rate | 99 m³/min |
| Fan Quantity / Type | 2 × Axial Propeller, Brushless DC Motor |
| Fan Motor Output | 2 × 125 W |
| Fan Speed | 650 rpm |
| Fan Discharge Direction | Horizontal |
| Heat Exchanger Fin Type | G-Fin Louvred |
| Heat Exchanger Tube Diameter | Φ7.94 mm, 2-row |
| Fin/Coil Treatment | Anti-Salt coating |
| Acoustics (ISO 3741) | |
| Sound Pressure Level — Heating Mode | 50 dB(A) |
| Sound Power Level — Heating Mode | 64 dB(A) |
| Sound Pressure Level — Cooling Mode | 50 dB(A) |
| Sound Power Level — Cooling Mode | 65 dB(A) |
| Compressor | |
| Compressor Type | BLDC Twin Rotary, Inverter Driven |
| Compressor Oil Type / Initial Charge | POE / 1,700 cc |
| Physical | |
| Net Dimensions (W × H × D) | 940 × 1,420 × 330 mm |
| Net Weight | 110.0 kg |
| Casing Material | Powder-coated electro-galvanised steel |
| Casing Colour | Earth Brown |
| Controls & Connectivity | |
| Control Module (required, sold separately) | MIM-E03CN (incl. Touch Controller MWR-WW10N) |
| Wi-Fi Connectivity | Optional — MIM-H04N Wi-Fi Kit (sold separately) |
| SmartThings App Compatible | Yes (requires MIM-H04N) |
| 2-Zone Control | Yes |
| PV-Enabled | Yes |
| Smart Grid Ready | Yes |
Frequently Asked Questions