Biasi Multipoint 16S Natural Gas Instantaneous Water Heater 30kW ErP A
HomeStore

Biasi Multipoint 16S Natural Gas Instantaneous Water Heater 30kW ErP A

Biasi Multipoint 16S Natural Gas Instantaneous Water Heater 30kW ErP A

$176.17

Original: $503.35

-65%
Biasi Multipoint 16S Natural Gas Instantaneous Water Heater 30kW ErP A

$503.35

$176.17

The Story

The Biasi Multipoint 16S (model code SV16S, MPN MPNG) is a 30kW room-sealed gas instantaneous water heater designed for properties with high or simultaneous hot water demand. Manufactured by BSG Caldaie a Gas S.p.A. in Pordenone, Italy — part of the Biasi Group — it delivers up to 16 litres per minute of continuous hot water on natural gas (G20, 20 mbar) and activates automatically from a minimum inlet pressure of just 0.2 bar (2.5 L/min). A microcomputer intelligent control system reads the water flow sensor, inlet temperature sensor and outlet temperature sensor simultaneously, adjusting the proportional gas valve in real time to hold the outlet at exactly the temperature set on the digital LCD touch panel — regardless of changes in flow rate or inlet temperature. The AI memory function retains the last set temperature so the unit is ready at the preferred setting from the first draw. Output is adjustable from 35°C to 65°C. ErP water heating energy efficiency class A (ηwh 80.5%), declared load profile XL. Appliance type C13/C33 — room-sealed fan-assisted — with a 60/100 mm coaxial flue (horizontal or vertical). IPX4 electrical protection rating. 2-year parts and labour guarantee when registered with Biasi UK within 30 days of purchase.

🔴 Gas Safe Registered Installation — Mandatory
Installation, commissioning, and servicing of the Biasi Multipoint 16S must be carried out by a Gas Safe registered engineer in full compliance with the Biasi installation manual, the Gas Safety (Installation and Use) Regulations 1998, and current Building Regulations. A 60/100 mm coaxial flue kit and a switchable fused spur must be provided. The Benchmark commissioning checklist must be completed and signed at handover. Annual servicing by a Gas Safe registered engineer is strongly recommended to maintain safe operation and warranty validity.
🟠 Natural Gas Only — Flue Kit Sold Separately
This listing is for the natural gas (G20, 20 mbar) version only — MPN MPNG. The unit leaves the factory set for G20; it must not be connected to LPG without first fitting the appropriate Biasi conversion kit (Gas Safe registered engineer task). A 60/100 mm coaxial flue assembly is required for installation and is not included — order the matching Biasi horizontal or vertical flue kit separately. The 2-year guarantee must be registered with Biasi UK within 30 days of purchase by calling 01922 714600.
🟢 Three Operating Modes — Normal / Auto / Eco
Press the @ function key in standby to cycle between three modes. Normal (default): user-set temperature, 35–65°C. Auto: the microcomputer automatically maps the outlet temperature to the measured inlet temperature — e.g. ≤15°C inlet → 45°C outlet, 22–27°C inlet → 40°C outlet — ideal for year-round comfort without manual seasonal adjustment. Eco: the microcomputer modulates gas supply to minimise consumption while maintaining the set temperature — best for lower-demand periods. All three modes are available at any set temperature within the 35–65°C range.
30 kW
Nominal heat input
27.4 kW
Max useful output G20
16 L/min
Max flow (25°C rise)
0.2 bar
Min inlet pressure
ErP A
ηwh 80.5%
2 yrs
Parts & labour guarantee
Microcomputer Real-Time Constant Temperature

The CPU chipset simultaneously reads the water flow sensor, inlet temperature sensor, and outlet temperature sensor, then adjusts the proportional gas valve within milliseconds to deliver the set temperature precisely. Unlike basic on/off instantaneous heaters that require manual tap-blending, the 16S holds the outlet at the set point whether one or two outlets are open — no adjustment needed mid-draw.

16 L/min — True Simultaneous Multipoint

At 16 L/min at a 25°C temperature rise (based on a ~12°C cold inlet delivering ~37°C at the outlet), the 16S is rated for genuine simultaneous use — a shower and a basin running concurrently without the temperature faltering. The 30kW nominal heat input (27.4kW useful output on G20) underpins this high flow capacity. Compared to the 14S (28kW / 14 L/min), the 16S provides approximately 14% more peak flow — meaningful in busy households or back-to-back commercial washroom use.

0.2 Bar Activation — Low-Pressure Compatible

The 16S fires at a minimum inlet pressure of 0.2 bar (0.02 MPa) and minimum flow rate of 2.5 L/min — among the lowest activation thresholds for a 30kW instantaneous heater. This makes it suitable for upper-floor flats, loft conversions, rural properties, and any location where mains pressure can be marginal. The fan-assisted type C room-sealed flue draws combustion air from outside, removing any dependency on room ventilation and widening the range of viable installation locations.

LCD Touch Panel — AI Memory — Live Gas Display

The digital LCD display shows the set outlet temperature, live flame feedback, fan status, and draw-off indicator. Two soft-touch buttons step temperature in 1°C increments from 35–48°C, then in 5°C steps to 65°C. The AI memory function retains the last-used temperature after power cycling — no reprogramming on restart. The function mode also displays real-time gas consumption in m³/h during operation, and cumulative water and gas usage over the appliance's lifetime — useful for running cost monitoring and maintenance planning.

Nine Safety Systems — Child Lock to 48°C

Nine independent safety circuits are built in: self-check protection, flame-out protection, over-heat protection, accidental power-cut protection, fan breakdown protection, electric overload protection, electric leakage protection, high wind pressure protection, and over-temperature protection. The child lock function prevents the temperature being raised above 48°C while the hot water outlet is open — the padlock icon flashes on the display when this threshold is approached, preventing accidental scalding.

NOx Class 6 — ErP A — Italian Manufacture

Made by BSG Caldaie a Gas S.p.A. in Pordenone, Italy. The 16S achieves NOx Class 6 — the highest available — with weighted NOx of 30.53 ppm (47 mg/kWh). ErP water heating efficiency Class A (ηwh 80.5%), declared load profile XL, confirming suitability for high-demand applications. Compliant with Gas Appliances Regulation (EU) 2016/426, Ecodesign Directive 2009/125/EC, EMC Directive 2014/30/EU, and Low Voltage Directive 2014/35/EU. Destination country certification: GB / IE.

Technical Specifications — Biasi Multipoint 16S (SV16S) — Natural Gas G20
Identity & Classification
Model / MPN Biasi Multipoint 16S — SV16S — MPNG
Appliance Type C13/C33 — room-sealed fan-assisted instantaneous
Gas Category II2H3P / II2H3B/P
Destination Country GB / IE
Heat & Flow Performance (G20 Natural Gas)
Nominal Heat Input (Hi) 30.0 kW
Max. Nominal Heat Output (G20) 27.4 kW
Min. Heat Input (G20) 9.5 kW
Min. Heat Output (G20) 8.7 kW
Max. Flow Rate (25°C rise) 16 L/min
Min. Activation Flow Rate 2.5 L/min
Min. Water Inlet Pressure 0.2 bar (0.02 MPa)
Max. Water Pressure 10 bar
Outlet Temperature Range 35°C – 65°C (1°C steps 35–48°C; 5°C steps 48–65°C)
Gas Supply (G20 Natural Gas)
Gas Type Natural Gas G20 — 2H
Nominal Gas Supply Pressure 20 mbar (2,000 Pa)
Min. Gas Supply Pressure 17 mbar (1,700 Pa)
Max. Gas Supply Pressure 25 mbar (2,500 Pa)
Max. Gas Flow Rate (Nom., Hi) 3.17 m³/h
Min. Gas Flow Rate (Hi) 1.01 m³/h
Flue & Combustion (G20)
Flue Duct Diameter Ø60 × Ø100 mm coaxial (C13 horizontal / C33 vertical)
Max. Flue Gas Temperature 118°C (at 60/80°C, G20)
CO₂ Content (Nominal Input) 5.16%
CO Content (Nominal Input) 229 ppm
ErP & Emissions
Water Heating Efficiency (ηwh) 80.5% — Class A
Declared Load Profile XL
Annual Fuel Consumption (AFC) 19 GJ
Annual Electricity Consumption (AEC) 14 kWh
NOx Class Class 6
Weighted NOx 30.53 ppm — 47 mg/kWh
Electrical & Physical
Power Supply 230 V ~ 50 Hz — switchable fused spur required
IP Rating IPX4
Ignition Water-controlled automatic pulse ignition
Indoor Sound Power Level (LWA) 63 dB(A)
Dimensions (H × W × D) 616 × 345 × 187 mm
Gas / Water Connections G ½" — gas inlet, cold water inlet, hot water outlet
Guarantee 2 years parts & labour — register within 30 days at Biasi UK: 01922 714600
Should I choose the 16S or the 14S?

The choice is straightforward once you quantify your peak demand. The 14S (28kW, 14 L/min) suits a 1–2 bathroom property with normal sequential use — one shower or one bath at a time. The 16S (30kW, 16 L/min) provides approximately 14% more peak flow capacity and is the better choice for properties with two bathrooms used concurrently, a large-volume shower head, or a busy kitchen alongside a bathroom in simultaneous use.

As a practical guide: at a typical UK winter cold inlet of ~10°C, the 16S delivers approximately 9.5 L/min at a comfortable 42°C outlet — sufficient for a good-flow shower and a running basin simultaneously. Both models are physically identical in size and use identical connections; the 16S costs marginally more but provides meaningful headroom for peak demand scenarios.

Does this heater work without mains electricity?

No. The Biasi Multipoint 16S requires a 230V ~ 50Hz mains supply for the microcomputer control system, the DC fan (forced combustion air and post-ventilation), the electronic ignition, and the LCD display. The unit will not ignite during a power cut — no electrical supply means no fan, no ignition, and no combustion.

A switchable fused spur must be installed adjacent to the appliance and must comply with current IEE Wiring Regulations. The socket or spur must not be located below the unit or in a position susceptible to water splashes. For properties with intermittent power supply, a small UPS may allow continued operation — discuss this with your installer and Biasi UK before specifying.

What flue kit do I need?

The Biasi Multipoint 16S uses a 60/100 mm coaxial flue system. For a standard horizontal through-wall installation (C13), you need a 60/100 mm horizontal flue kit supplying the terminal, coaxial pipe, elbow, seals, and wall fixings. For vertical roof discharge (C33), the appropriate vertical terminal kit is required.

For longer runs or routes that require bends around obstacles, extension pipes and additional 90° or 45° elbows are available from Biasi. Maximum permitted flue lengths vary with the number of bends — consult the installation manual's flue duct length table before finalising the installation position. The flue must terminate in a location complying with Building Regulations Part J and must not discharge into a common flue system.

How do I register the guarantee and what does it cover?

The 2-year parts and labour guarantee must be registered by calling Biasi UK on 01922 714600 within 30 days of purchase. Have your installer's Gas Safe registration details ready — Biasi require these to validate the warranty.

The guarantee covers manufacturing defects in materials and workmanship where the appliance has been installed and commissioned in accordance with the Biasi installation manual and the Benchmark commissioning checklist has been completed. It does not cover damage from installation errors, use of the incorrect gas type, inadequate water quality, or failure to carry out the recommended annual service. Annual servicing by a Gas Safe registered engineer is strongly advised to maintain warranty validity.

Can the unit be converted from natural gas to LPG?

Yes — the Multipoint 16S can be converted between natural gas (G20) and LPG (G30 butane / G31 propane) using the appropriate Biasi conversion kit. Gas conversion is a Gas Safe registered engineer task only — it involves changing the burner injectors, adjusting gas valve pressure settings, and updating the appliance data plate.

Do not operate the unit on a gas type different from its current setting without prior conversion. Biasi UK supplies conversion kits — contact them at 01922 714600 or via biasi.co.uk. Converted units must be recommissioned with the Benchmark checklist updated to reflect the new gas type. This listing is for the G20 natural gas factory-set version only.

What do the fault codes on the display mean, and what should I do?

When the onboard diagnostics detect an abnormal condition the LCD screen displays a flashing fault code rather than simply stopping without explanation. For most codes, the recommended first step is: close the hot water outlet, press the On/Off button to switch the unit off, wait a few seconds, switch back on, then reopen the outlet. This clears transient faults such as ignition failure after a gas interruption, where air in the supply pipe causes several retry cycles before the flame establishes.

If the fault code persists after two or three attempts, turn off the gas valve and cut the power, and contact your Gas Safe registered engineer. A full list of error codes and their meanings is provided in Section 6.2 of the Biasi Multipoint installation manual, downloadable from biasi.co.uk. Do not attempt to repair the unit yourself — any interference with sealed components is prohibited and may cause fire, explosion, or loss of life.

Biasi Multipoint 16S Natural Gas Instantaneous Water Heater 30kW ErP A - Image 2

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

Biasi Multipoint 16S Natural Gas Instantaneous Water Heater 30kW ErP A - Image 3

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

Description

The Biasi Multipoint 16S (model code SV16S, MPN MPNG) is a 30kW room-sealed gas instantaneous water heater designed for properties with high or simultaneous hot water demand. Manufactured by BSG Caldaie a Gas S.p.A. in Pordenone, Italy — part of the Biasi Group — it delivers up to 16 litres per minute of continuous hot water on natural gas (G20, 20 mbar) and activates automatically from a minimum inlet pressure of just 0.2 bar (2.5 L/min). A microcomputer intelligent control system reads the water flow sensor, inlet temperature sensor and outlet temperature sensor simultaneously, adjusting the proportional gas valve in real time to hold the outlet at exactly the temperature set on the digital LCD touch panel — regardless of changes in flow rate or inlet temperature. The AI memory function retains the last set temperature so the unit is ready at the preferred setting from the first draw. Output is adjustable from 35°C to 65°C. ErP water heating energy efficiency class A (ηwh 80.5%), declared load profile XL. Appliance type C13/C33 — room-sealed fan-assisted — with a 60/100 mm coaxial flue (horizontal or vertical). IPX4 electrical protection rating. 2-year parts and labour guarantee when registered with Biasi UK within 30 days of purchase.

🔴 Gas Safe Registered Installation — Mandatory
Installation, commissioning, and servicing of the Biasi Multipoint 16S must be carried out by a Gas Safe registered engineer in full compliance with the Biasi installation manual, the Gas Safety (Installation and Use) Regulations 1998, and current Building Regulations. A 60/100 mm coaxial flue kit and a switchable fused spur must be provided. The Benchmark commissioning checklist must be completed and signed at handover. Annual servicing by a Gas Safe registered engineer is strongly recommended to maintain safe operation and warranty validity.
🟠 Natural Gas Only — Flue Kit Sold Separately
This listing is for the natural gas (G20, 20 mbar) version only — MPN MPNG. The unit leaves the factory set for G20; it must not be connected to LPG without first fitting the appropriate Biasi conversion kit (Gas Safe registered engineer task). A 60/100 mm coaxial flue assembly is required for installation and is not included — order the matching Biasi horizontal or vertical flue kit separately. The 2-year guarantee must be registered with Biasi UK within 30 days of purchase by calling 01922 714600.
🟢 Three Operating Modes — Normal / Auto / Eco
Press the @ function key in standby to cycle between three modes. Normal (default): user-set temperature, 35–65°C. Auto: the microcomputer automatically maps the outlet temperature to the measured inlet temperature — e.g. ≤15°C inlet → 45°C outlet, 22–27°C inlet → 40°C outlet — ideal for year-round comfort without manual seasonal adjustment. Eco: the microcomputer modulates gas supply to minimise consumption while maintaining the set temperature — best for lower-demand periods. All three modes are available at any set temperature within the 35–65°C range.
30 kW
Nominal heat input
27.4 kW
Max useful output G20
16 L/min
Max flow (25°C rise)
0.2 bar
Min inlet pressure
ErP A
ηwh 80.5%
2 yrs
Parts & labour guarantee
Microcomputer Real-Time Constant Temperature

The CPU chipset simultaneously reads the water flow sensor, inlet temperature sensor, and outlet temperature sensor, then adjusts the proportional gas valve within milliseconds to deliver the set temperature precisely. Unlike basic on/off instantaneous heaters that require manual tap-blending, the 16S holds the outlet at the set point whether one or two outlets are open — no adjustment needed mid-draw.

16 L/min — True Simultaneous Multipoint

At 16 L/min at a 25°C temperature rise (based on a ~12°C cold inlet delivering ~37°C at the outlet), the 16S is rated for genuine simultaneous use — a shower and a basin running concurrently without the temperature faltering. The 30kW nominal heat input (27.4kW useful output on G20) underpins this high flow capacity. Compared to the 14S (28kW / 14 L/min), the 16S provides approximately 14% more peak flow — meaningful in busy households or back-to-back commercial washroom use.

0.2 Bar Activation — Low-Pressure Compatible

The 16S fires at a minimum inlet pressure of 0.2 bar (0.02 MPa) and minimum flow rate of 2.5 L/min — among the lowest activation thresholds for a 30kW instantaneous heater. This makes it suitable for upper-floor flats, loft conversions, rural properties, and any location where mains pressure can be marginal. The fan-assisted type C room-sealed flue draws combustion air from outside, removing any dependency on room ventilation and widening the range of viable installation locations.

LCD Touch Panel — AI Memory — Live Gas Display

The digital LCD display shows the set outlet temperature, live flame feedback, fan status, and draw-off indicator. Two soft-touch buttons step temperature in 1°C increments from 35–48°C, then in 5°C steps to 65°C. The AI memory function retains the last-used temperature after power cycling — no reprogramming on restart. The function mode also displays real-time gas consumption in m³/h during operation, and cumulative water and gas usage over the appliance's lifetime — useful for running cost monitoring and maintenance planning.

Nine Safety Systems — Child Lock to 48°C

Nine independent safety circuits are built in: self-check protection, flame-out protection, over-heat protection, accidental power-cut protection, fan breakdown protection, electric overload protection, electric leakage protection, high wind pressure protection, and over-temperature protection. The child lock function prevents the temperature being raised above 48°C while the hot water outlet is open — the padlock icon flashes on the display when this threshold is approached, preventing accidental scalding.

NOx Class 6 — ErP A — Italian Manufacture

Made by BSG Caldaie a Gas S.p.A. in Pordenone, Italy. The 16S achieves NOx Class 6 — the highest available — with weighted NOx of 30.53 ppm (47 mg/kWh). ErP water heating efficiency Class A (ηwh 80.5%), declared load profile XL, confirming suitability for high-demand applications. Compliant with Gas Appliances Regulation (EU) 2016/426, Ecodesign Directive 2009/125/EC, EMC Directive 2014/30/EU, and Low Voltage Directive 2014/35/EU. Destination country certification: GB / IE.

Technical Specifications — Biasi Multipoint 16S (SV16S) — Natural Gas G20
Identity & Classification
Model / MPN Biasi Multipoint 16S — SV16S — MPNG
Appliance Type C13/C33 — room-sealed fan-assisted instantaneous
Gas Category II2H3P / II2H3B/P
Destination Country GB / IE
Heat & Flow Performance (G20 Natural Gas)
Nominal Heat Input (Hi) 30.0 kW
Max. Nominal Heat Output (G20) 27.4 kW
Min. Heat Input (G20) 9.5 kW
Min. Heat Output (G20) 8.7 kW
Max. Flow Rate (25°C rise) 16 L/min
Min. Activation Flow Rate 2.5 L/min
Min. Water Inlet Pressure 0.2 bar (0.02 MPa)
Max. Water Pressure 10 bar
Outlet Temperature Range 35°C – 65°C (1°C steps 35–48°C; 5°C steps 48–65°C)
Gas Supply (G20 Natural Gas)
Gas Type Natural Gas G20 — 2H
Nominal Gas Supply Pressure 20 mbar (2,000 Pa)
Min. Gas Supply Pressure 17 mbar (1,700 Pa)
Max. Gas Supply Pressure 25 mbar (2,500 Pa)
Max. Gas Flow Rate (Nom., Hi) 3.17 m³/h
Min. Gas Flow Rate (Hi) 1.01 m³/h
Flue & Combustion (G20)
Flue Duct Diameter Ø60 × Ø100 mm coaxial (C13 horizontal / C33 vertical)
Max. Flue Gas Temperature 118°C (at 60/80°C, G20)
CO₂ Content (Nominal Input) 5.16%
CO Content (Nominal Input) 229 ppm
ErP & Emissions
Water Heating Efficiency (ηwh) 80.5% — Class A
Declared Load Profile XL
Annual Fuel Consumption (AFC) 19 GJ
Annual Electricity Consumption (AEC) 14 kWh
NOx Class Class 6
Weighted NOx 30.53 ppm — 47 mg/kWh
Electrical & Physical
Power Supply 230 V ~ 50 Hz — switchable fused spur required
IP Rating IPX4
Ignition Water-controlled automatic pulse ignition
Indoor Sound Power Level (LWA) 63 dB(A)
Dimensions (H × W × D) 616 × 345 × 187 mm
Gas / Water Connections G ½" — gas inlet, cold water inlet, hot water outlet
Guarantee 2 years parts & labour — register within 30 days at Biasi UK: 01922 714600
Should I choose the 16S or the 14S?

The choice is straightforward once you quantify your peak demand. The 14S (28kW, 14 L/min) suits a 1–2 bathroom property with normal sequential use — one shower or one bath at a time. The 16S (30kW, 16 L/min) provides approximately 14% more peak flow capacity and is the better choice for properties with two bathrooms used concurrently, a large-volume shower head, or a busy kitchen alongside a bathroom in simultaneous use.

As a practical guide: at a typical UK winter cold inlet of ~10°C, the 16S delivers approximately 9.5 L/min at a comfortable 42°C outlet — sufficient for a good-flow shower and a running basin simultaneously. Both models are physically identical in size and use identical connections; the 16S costs marginally more but provides meaningful headroom for peak demand scenarios.

Does this heater work without mains electricity?

No. The Biasi Multipoint 16S requires a 230V ~ 50Hz mains supply for the microcomputer control system, the DC fan (forced combustion air and post-ventilation), the electronic ignition, and the LCD display. The unit will not ignite during a power cut — no electrical supply means no fan, no ignition, and no combustion.

A switchable fused spur must be installed adjacent to the appliance and must comply with current IEE Wiring Regulations. The socket or spur must not be located below the unit or in a position susceptible to water splashes. For properties with intermittent power supply, a small UPS may allow continued operation — discuss this with your installer and Biasi UK before specifying.

What flue kit do I need?

The Biasi Multipoint 16S uses a 60/100 mm coaxial flue system. For a standard horizontal through-wall installation (C13), you need a 60/100 mm horizontal flue kit supplying the terminal, coaxial pipe, elbow, seals, and wall fixings. For vertical roof discharge (C33), the appropriate vertical terminal kit is required.

For longer runs or routes that require bends around obstacles, extension pipes and additional 90° or 45° elbows are available from Biasi. Maximum permitted flue lengths vary with the number of bends — consult the installation manual's flue duct length table before finalising the installation position. The flue must terminate in a location complying with Building Regulations Part J and must not discharge into a common flue system.

How do I register the guarantee and what does it cover?

The 2-year parts and labour guarantee must be registered by calling Biasi UK on 01922 714600 within 30 days of purchase. Have your installer's Gas Safe registration details ready — Biasi require these to validate the warranty.

The guarantee covers manufacturing defects in materials and workmanship where the appliance has been installed and commissioned in accordance with the Biasi installation manual and the Benchmark commissioning checklist has been completed. It does not cover damage from installation errors, use of the incorrect gas type, inadequate water quality, or failure to carry out the recommended annual service. Annual servicing by a Gas Safe registered engineer is strongly advised to maintain warranty validity.

Can the unit be converted from natural gas to LPG?

Yes — the Multipoint 16S can be converted between natural gas (G20) and LPG (G30 butane / G31 propane) using the appropriate Biasi conversion kit. Gas conversion is a Gas Safe registered engineer task only — it involves changing the burner injectors, adjusting gas valve pressure settings, and updating the appliance data plate.

Do not operate the unit on a gas type different from its current setting without prior conversion. Biasi UK supplies conversion kits — contact them at 01922 714600 or via biasi.co.uk. Converted units must be recommissioned with the Benchmark checklist updated to reflect the new gas type. This listing is for the G20 natural gas factory-set version only.

What do the fault codes on the display mean, and what should I do?

When the onboard diagnostics detect an abnormal condition the LCD screen displays a flashing fault code rather than simply stopping without explanation. For most codes, the recommended first step is: close the hot water outlet, press the On/Off button to switch the unit off, wait a few seconds, switch back on, then reopen the outlet. This clears transient faults such as ignition failure after a gas interruption, where air in the supply pipe causes several retry cycles before the flame establishes.

If the fault code persists after two or three attempts, turn off the gas valve and cut the power, and contact your Gas Safe registered engineer. A full list of error codes and their meanings is provided in Section 6.2 of the Biasi Multipoint installation manual, downloadable from biasi.co.uk. Do not attempt to repair the unit yourself — any interference with sealed components is prohibited and may cause fire, explosion, or loss of life.

Biasi Multipoint 16S Natural Gas Instantaneous Water Heater 30kW ErP A | AIZO Quality Heating